Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Colloid Interface Sci ; 667: 553-562, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38657539

RESUMO

The construction of stable hierarchical surfaces through structural engineering is the key to improve reactive active sites and cycle stability to achieve high cycle performance of supercapacitors (SCs). In this work, the NiCo-LDH nanoflower as a structure guide agent was used to support NiCoB nanosheets to form a dense and stable hierarchical structure, thereby exposing more active sites and improving cycle stability. Due to the hierarchical stable surface structure, the NiCoB-0.3@NiCo-LDH-30 electrode has an excellent specific capacitance of 2710F g-1 at 1 A/g due to the excellent electrochemical active surface area (1259 mF cm-2), improving the OH- diffusion coefficient (2.4 × 10-9 cm2 s-1) and decreasing ionic diffusion barrier. After 5000 cycles, NiCoB-0.3@NiCo-LDH-30 electrode still has 92.6 % initial specific capacitance. In order to balance the energy density decrease caused by the capacitance imbalance between positive and negative electrodes, the cubed carbon (Co-C) derived from cobalt metal organic frameworks (Co-MOFs) as cathode with a good specific capacitance of 220F g-1 at 1 A/g is prepared. The assembled NiCoB-0.3@NiCo-LDH-30//Co-C hybrid SCs (HSCs), which are assembled with NiCoB-0.3@NiCo-LDH-30 electrode as anode and Co-C electrode as cathode, displays an energy density of 75 Wh kg-1 at a power density of 741 W kg-1.

2.
Front Pediatr ; 12: 1347637, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38596248

RESUMO

The introduction of new internal fixation devices and arthroscopic techniques has led to significant changes in the surgical treatment of tibial eminence fractures (TEFs) in children. In recent years, arthroscopic surgery has arisen as the gold standard for the treatment of TEFs. This popularity of arthroscopic techniques has reduced surgical complications and improved patient prognosis. In this paper, we investigate the current situation of the use of arthroscopic fixation techniques for pediatric TEFs. We searched the PubMed database using the terms "arthroscopic treatment and tibial eminence," "arthroscopic treatment and tibial spine," "tibial eminence avulsion", "tibial spine fracture", with no limit on the year of publication. From these articles, we reviewed the use of various arthroscopic TEFs fixation techniques reported in the current literature. Overall, we found that the choice of fixation method seems to have no effect on clinical outcomes or imaging results. However, if an easy, strong fixation that is less prone to epiphyseal damage is desired, as a junior practitioner, the anchor technique should be mastered first, whereas for senior practitioners, a variety of fixation techniques for TEFs should be mastered, including anchors, sutures, and screws, so that personalized fixation can be achieved with the least amount of trauma, operative time, and complications. Higher quality studies are needed in the future to provide Useful evidence to determine the optimal fixation technique in terms of clinical outcomes, function, and complications.

3.
Nanomicro Lett ; 16(1): 149, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38466478

RESUMO

Achieving flexible electronics with comfort and durability comparable to traditional textiles is one of the ultimate pursuits of smart wearables. Ink printing is desirable for e-textile development using a simple and inexpensive process. However, fabricating high-performance atop textiles with good dispersity, stability, biocompatibility, and wearability for high-resolution, large-scale manufacturing, and practical applications has remained challenging. Here, water-based multi-walled carbon nanotubes (MWCNTs)-decorated liquid metal (LM) inks are proposed with carbonaceous gallium-indium micro-nanostructure. With the assistance of biopolymers, the sodium alginate-encapsulated LM droplets contain high carboxyl groups which non-covalently crosslink with silk sericin-mediated MWCNTs. E-textile can be prepared subsequently via printing technique and natural waterproof triboelectric coating, enabling good flexibility, hydrophilicity, breathability, wearability, biocompatibility, conductivity, stability, and excellent versatility, without any artificial chemicals. The obtained e-textile can be used in various applications with designable patterns and circuits. Multi-sensing applications of recognizing complex human motions, breathing, phonation, and pressure distribution are demonstrated with repeatable and reliable signals. Self-powered and energy-harvesting capabilities are also presented by driving electronic devices and lighting LEDs. As proof of concept, this work provides new opportunities in a scalable and sustainable way to develop novel wearable electronics and smart clothing for future commercial applications.

4.
Orthop Surg ; 16(2): 481-489, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38174408

RESUMO

OBJECTIVE: Currently, there is no simple and valid method to predict the length and size of the native anterior cruciate ligament (ACL) in each adult patient who will undergo ACL reconstruction. This study aimed to develop an imaging prediction method that can predict the length and size of ACL grafts using the intact posterior cruciate ligament (PCL), in order to enhance the graft preparation individualized sizing. METHODS: Three hundred and nineteen patients aged 18 years or older who underwent magnetic resonance imaging (MRI) of the knee at an orthopaedic clinic between September 9, 2021, and February 5, 2023, were included. The length, sagittal diameter, and coronal diameter of the ACL and PCL were measured in all patients, and F-test were performed to explore linear relationship between ligament measurements. RESULTS: Equations were established to predict a variable of the native ACL for the corresponding variable of the intact PCL (i.e., sagittal diameter of the ACL = 4.32 + 1.08 × sagittal diameter of the PCL, and coronal diameter of the ACL = 2.45 + 0.59 × coronal diameter of the PCL, length of the male ACL = 10.92 + 0.64 × length of the male PCL, length of the female ACL = 11.76 + 0.58 × length of the female PCL) (R2 = 0.532; R2 = 0.417; R2 = 0.488; R2 = 0.509; respectively). CONCLUSIONS: The length and size of the intact PCL in cases without PCL buckling are predictors of the length and size of the native ACL in adults, respectively. The use of this information to optimize graft diameter may lower the rates of ACL graft failure in the future.


Assuntos
Lesões do Ligamento Cruzado Anterior , Ligamento Cruzado Posterior , Adulto , Humanos , Masculino , Feminino , Ligamento Cruzado Anterior , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Ligamento Cruzado Posterior/cirurgia , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/patologia , Imageamento por Ressonância Magnética , China
5.
Adv Sci (Weinh) ; 10(23): e2301398, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37271896

RESUMO

The fast OH- transfer between hydroxide layers is the key to enhancing the charge storage efficiency of layered double hydroxides (LDH)-based supercapacitors (SCs). Constructing interlayer reactive sites in LDH is much expected but still a huge challenge. In this work, CdS nano-dots (NDs) are introduced to interlayers of ultra-thin NiFe-LDH (denoted CdSinter. -NiFe-LDH), promoting the interlayer ions flow for higher redox activity. The excellent performance is not only due to the enlarged layer spacing (from 0.70 to 0.81 nm) but also stems from anchored interlayer reactive units and the undamaged original layered structure of LDH, which contribute to the improvement of OH- diffusion coefficient (1.6 × 10-8  cm2  s-1 ) and electrochemical active area (601 mF cm-2 ) better than that of CdS NDs on the surface of NiFe-LDH (2.1 × 10-9  cm2  s-1 and 350 mF cm-2 ). The champion CdSinter. -NiFe-LDH electrode displays high capacitance of 3330.0 F g-1 at 1 A g-1 and excellent retention capacitance of 90.9% at 10 A g-1 , which is better than the NiFe-LDH with CdS NDs on the surface (1966.6 F g-1 ). Moreover, the assembled     asymmetric SCs (ASC) device demonstrate an outstanding energy density/power density (121.56 Wh kg-1 /754.5 W kg-1 ).

6.
Chin Med J (Engl) ; 136(1): 73-81, 2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36780427

RESUMO

BACKGROUND: Synovectomy has been introduced into total knee arthroplasty (TKA) with the aim of relieving pain and inflammation of the synovium. However, there are no long-term, comparative data to evaluate the effect of synovectomy in TKA. This study was aimed at assessing pain, function, and complications in patients undergoing synovectomy during TKA for osteoarthritis (OA) at long-term follow-up. METHODS: This was a prospective randomized controlled trial of 42 consecutive patients who underwent staged bilateral TKA. Patients undergoing the first-side TKA were allocated to receive TKA with or without synovectomy followed by a 3-month washout period and crossover to the other strategy for the opposite-side TKA. The overall efficacy of both strategies was evaluated by determination of blood loss, the Knee Society score (KSS), and knee inflammation conditions during a 3-month postoperative period. The postoperative pain, range of motion (ROM), and complications were sequentially evaluated to compare the two groups until 10 years after surgery. RESULTS: At the 10-year follow-up, both groups had a similarly significantly improved ROM (114.88 ±â€Š9.84° vs. 114.02 ±â€Š9.43°, t  = 0.221, P  = 0.815) and pain relief with no differences between the two groups (1.0 [1.0] vs. 1.0 [1.5], U  = 789.500, P  = 0.613). Similar changes in total blood loss, KSS, and knee inflammation were found in both groups during 3 months postoperatively ( P  > 0.05). Additionally, there was no significant difference regarding complications and satisfaction between the two groups ( P  > 0.05). CONCLUSIONS: Synovectomy in conjunction with TKA for primary OA does not seem to provide any benefit regarding postoperative pain, ROM, and satisfaction during a 10-year follow-up. In addition, it may not result in more blood loss and increased incidence of long-term complications. Based on our long-term findings, it should not be performed routinely. TRIAL REGISTRATION: Chinese Clinical Trial Registry, ChiCTR-INR-16008245; https://www.chictr.org.cn/showproj.aspx?proj=13334 .


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Sinovectomia/efeitos adversos , Sinovectomia/métodos , Osteoartrite do Joelho/cirurgia , Estudos Prospectivos , Dor Pós-Operatória , Inflamação/etiologia , Amplitude de Movimento Articular , Articulação do Joelho/cirurgia , Resultado do Tratamento , Prótese do Joelho/efeitos adversos
7.
J Colloid Interface Sci ; 631(Pt A): 143-154, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36371823

RESUMO

Improving the lifetime and energy density of energy storage devices has always been a major challenge. Here, CoS2 with a hollow structure derived from zeolite-imidazolate framework-67 was reconstructed on Co(OH)F nanowires. Co(OH)F nanowires contribute to ion/electron transmission and reduce transmission resistance, thereby promoting the stability of the electrode. CoS2 with a hollow porous structure contributes to the full infiltration of electrolytes, shortens the ion transmission distance, accelerates the redox reactions, and alleviates the volume expansion, thus improving the pseudocapacitance. Therefore, the prepared Co(OH)F/CoS2 displayed excellent specific capacity (233 mAh g-1). The assembled HSC Co(OH)F/CoS2//activated carbon in KOH solution could achieve a considerable energy density (63.9 Wh kg-1). Surprisingly, the specific capacitance accounts for 107.0% of the primary capacitance (20,000 cycles), demonstrating great cycling stability. This work presents a conceptual approach for the construction of abundant and promising electrodes for HSCs.

8.
Front Neurol ; 13: 1007992, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36425796

RESUMO

Objectives: To dynamically investigate otolith function in patients with benign paroxysmal positional vertigo (BPPV) before, after, and 1 month after repositioning, and explore the possible compensation mechanisms. Methods: Thirty-six patients confirmed with BPPV (canal lithiasis) treated in our hospital between August 2020 and March 2021, as well as 36 health controls matched for age and gender (normal control group, NC group) were enrolled. For NC group, the virtual reality (VR) auxiliary static subjective visual vertical (SVV), subjective visual horizontal (SVH), and SVV of dynamic unilateral centrifugation (DUC), were measured at inclusion. For the BPPV group, visual analog scale (VAS) was used to assess the vertigo degree, while static SVV, SVH, and DUC were performed before, after, and 1 month after repositioning. First, we compare the deviations of SVV0/SVH0° when the subject's head is in the positive position, and SVV of DUC between BPPV and NC groups before repositioning, after which we compared the deviations in SVV45, SVV90, SVH45, SVH90°, and SVV of DUC between the affected and unaffected sides before repositioning. Finally, paired t-test was used to compare the VAS score, deviations in static SVV0, SVV45, SVV90, SVH0, SVH45, and SVH90°, and deviations in SVV of DUC before, after, and 1 month after repositioning. (Here, 0, 45, and 90° refer to the angle which the center axis of head deviates from the gravity line.). Results: SVV0 SVH0°, and SVV of DUC at 120 and 180°/s 0 significantly differed between BPPV and NC group before repositioning. The deviations in SVV45, SVV90, SVH45, SVH90°, and SVV of DUC at 120°/s-2 and 180°/s-4.5 did not significantly differ between bilateral sides in BPPV patients before repositioning. The deviation in SVH90° was significantly lower after repositioning than before. The deviation in SVH45° was significantly higher 1 month after repositioning than before. The deviation angle of SVV of DUC at 180°/s-0 was significantly lower after repositioning than before. The vertigo VAS score of patient with BPPV continued to decrease after repositioning. Conclusion: Before repositioning, the otolithic organ function of BPPV patients was obviously impaired, with no significant difference between the healthy and affected ear. After repositioning, there was a transient recovery of otolithic organ dysfunction followed by a sustained decline to similar levels to before repositioning.

9.
J Int Med Res ; 50(11): 3000605221121954, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36324250

RESUMO

OBJECTIVE: Diffusion tensor imaging research on the anterior cruciate ligament (ACL) is limited, and no study has revealed the ACL fibrous microstructure by 7.0-Tesla magnetic resonance imaging. Therefore, we used magnetic resonance imaging to assess the ACL. METHODS: Eight porcine ACLs were investigated by diffusion tensor imaging. Imaging was performed with a 7.0-Tesla scanner using a diffusion-weighted two-dimensional spin-echo echo-planar imaging pulse sequence optimised for muscle. The diffusion tensor eigenparameters, fractional anisotropy (FA), and apparent diffusion coefficient (ADC) were used for bones and muscles. Three-dimensional projection maps of the principal eigenvectors were plotted to visualise the microstructure. RESULTS: The mean FA and ADC for the ACL were 0.27 ± 0.079 and 0.0012 ± 0.0005, respectively. There were no significant differences between the values in the proximal and distal portions . However, the ADC was smaller in the centre than on the sides (0.0015 ± 0.0007), and the mean FA was larger in the centre than on the sides (0.42 ± 0.23). The ACL fibres were parallel on the proximal and distal sides but interweaved in the centre. CONCLUSIONS: These findings may be beneficial for artificial ligaments.


Assuntos
Ligamento Cruzado Anterior , Imagem de Tensor de Difusão , Suínos , Animais , Ligamento Cruzado Anterior/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Anisotropia , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética
10.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 36(6): 698-702, 2022 Jun 15.
Artigo em Chinês | MEDLINE | ID: mdl-35712926

RESUMO

Objective: To investigate the effectiveness of arthroscopic distal clavicle resection for the symptomatic acromioclavicular joint arthritis. Methods: The clinical data of 14 patients with symptomatic acromioclavicular joint arthritis treated by arthroscopic indirect distal clavicle resection between January 2020 and March 2021 were retrospectively analyzed. There were 5 males and 9 females with an average age of 46.3 years (range, 18-57 years). The 4 cases of left shoulder and 10 cases of right shoulder were accompanied with acromial impingement, without the history of shoulder trauma. The average disease duration was 20.4 months (range, 9-48 months), and the average visual analogue scale (VAS) score was 7.6 (range, 5-9) preoperatively. The results were evaluated using the University of California Los Angeles (UCLA) shoulder rating score before and after operation, further, the patient satisfaction rate was also calculated. Results: All 14 patients were followed up 5-18 months, with an average of 13 months. There was no postoperative pain of acromioclavicular joint in 12 patients; 1 case had occasional mild pain, which could be controlled by painkillers. Moreover, there was only 1 acromioclavicular joint subluxation due to early fitness training at 2 weeks postoperatively, and the symptoms gradually relieved after 1 month of conservative treatments. The UCLA score was 22.1±6.2 preoperatively, which improved to 30.2±3.4 at last follow-up, showing significant difference ( t=5.359, P<0.001). The patient satisfaction rate was 92.9%, with 12 excellent cases, 1 good case, and 1 fair case. Conclusion: Arthroscopic distal clavicle resection for symptomatic acromioclavicular arthritis is a safe, reliable, and repeatable procedure.


Assuntos
Articulação Acromioclavicular , Artrite , Luxações Articulares , Articulação Acromioclavicular/lesões , Articulação Acromioclavicular/cirurgia , Artrite/complicações , Artrite/cirurgia , Artroscopia/métodos , Clavícula/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
11.
J Colloid Interface Sci ; 608(Pt 3): 3049-3058, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-34838320

RESUMO

The construction of heterostructure could enhance the electron transfer efficiency and increase the number of active sites, which can further develop high-performance electrode materials of supercapacitors. Herein, (Ni, Co)Se2 nanorod arrays were prepared based on the NiCo-LDH derived from a conical ZIF-L. Significantly, the single nanorod is composed of interconnected NiSe2 and CoSe2 nanoparticles, the heterostructure can expose higher conductivity, more sufficient redox reaction active sites and larger specific surface area. The as-obtained CF@(Ni, Co)Se2 achieved a high specific capacity of 188.8 mAh g-1 at the current density of 1.0 A g-1 and an outstanding cycling stability with a high capacity retention of 90% after 8000 cycles. Finally, an hybrid supercapacitor device composed of activated carbon (AC) as negative electrode and CF@(Ni, Co)Se2 as positive electrode was designed, which revealed an ideal voltage window of 0-1.6 V and exhibited a great energy density of 36.02 Wh kg-1 at the power density of 800 W kg-1, such surpassing energy storage characteristics evidently testify that (Ni, Co)Se2 nanorod arrays can be as the potential electrode material to promote the development of high-performance supercapacitors.

12.
J Colloid Interface Sci ; 610: 427-437, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-34929513

RESUMO

Achieving a high volumetric energy density supercapacitor is of great significance for portable energy storage devices while still a major challenge. Herein, we design and fabricate self-supporting electrodes using CoZnNi oxyphosphide nanoarrays sandwiched graphene/carbon nanotube (CZNP/GC) film with highly exposed active sites. Benefitting from the modified electronic structures, high accessible surface areas, and the integrated structure, the well-designed CZNP/GC electrode exhibits an ultra-high volumetric capacitance of 2096.4 F cm-3 at a current density of 1 A g-1. Moreover, a high-performance negative electrode of carbon/rGO/CNTs (C/GC) is also fabricated using the same CoZn-metal-organic frameworks precursor. The assembled asymmetric supercapacitor CZNP/GC//C/GC displays an ultra-high volumetric energy density of 71.8 W h L-1 at 960 W L-1. After 6000 charge-discharge cycles, the device still maintains 85.6% of the original capacitance. The density functional theory calculation is studied and the negative adsorption energy proves that the OH- adsoption process onto the surface of as-prepared electrode is thermodynamically favorable, facilitating the electrochemical reaction. This work provides a new option in constructing tailorable electrodes with a well-defined hierarchical structure for supercapacitor and beyond.

13.
Am J Sports Med ; 49(10): 2795-2809, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34213976

RESUMO

BACKGROUND: In this study, we investigated the in vitro and in vivo chondrogenic capacity of kartogenin (KGN)-enhanced bone marrow-derived mesenchymal stem cells (BMSCs) for cartilage regeneration. PURPOSE: To determine (1) whether functionalized nanographene oxide (NGO) can effectively deliver KGN into BMSCs and (2) whether KGN would enhance BMSCs during chondrogenesis in vitro and in vivo in an animal model. STUDY DESIGN: Controlled laboratory study. METHODS: Functionalized NGO with line chain amine-terminated polyethylene glycol (PEG) and branched polyethylenimine (BPEI) were used to synthesize biocompatible NGO-PEG-BPEI (PPG) and for loading hydrophobic KGN molecules noncovalently via π-π stacking and hydrophobic interactions (PPG-KGN). Then, PPG-KGN was used for the intracellular delivery of hydrophobic KGN by simple mixing and co-incubation with BMSCs to acquire KGN-enhanced BMSCs. The chondrogenic efficacy of KGN-enhanced BMSCs was evaluated in vitro. In vivo, osteoarthritis (OA) was induced by anterior cruciate ligament transection in rats. A total of 5 groups were established: normal (OA treated with nothing), phosphate-buffered saline (PBS; intra-articular injection of PBS), PPG-KGN (intra-articular injection of PPG-KGN), BMSCs (intra-articular injection of BMSCs), and BMSCs + PPG-KGN (intra-articular injection of PPG-KGN-preconditioned BMSCs). At 6 and 9 weeks after the surgical induction of OA, the rats received intra-articular injections of PPG-KGN, BMSCs, or KGN-enhanced BMSCs. At 14 weeks after the surgical induction of OA, radiographic and behavioral evaluations as well as histological analysis of the knee joints were performed. RESULTS: The in vitro study showed that PPG could be rapidly uptaken in the first 4 hours after incubation, reaching saturation at 12 hours and accumulating in the lysosome and cytoplasm of BMSCs. Thus, PPG-KGN could enhance the efficiency of the intracellular delivery of KGN, which showed a remarkably high chondrogenic differentiation capacity of BMSCs. When applied to an OA model of cartilage injuries in rats, PPG-KGN-preconditioned BMSCs contributed to protection from joint space narrowing, pathological mineralization, OA development, and OA-induced pain, as well as improved tissue regeneration, as evidenced by radiographic, weightbearing, and histological findings. CONCLUSION: Our results demonstrate that KGN-enhanced BMSCs showed markedly improved capacities for chondrogenesis and articular cartilage repair. We believe that this work demonstrates that a multifunctional nanoparticle-based drug delivery system could be beneficial for stem cell therapy. Our results present an opportunity to reverse the symptoms and pathophysiology of OA. CLINICAL RELEVANCE: The intracellular delivery of KGN to produce BMSCs with enhanced chondrogenic potential may offer a new approach for the treatment of OA.


Assuntos
Cartilagem Articular , Células-Tronco Mesenquimais , Osteoartrite do Joelho , Anilidas , Animais , Medula Óssea , Condrogênese , Injeções Intra-Articulares , Osteoartrite do Joelho/tratamento farmacológico , Ácidos Ftálicos , Ratos
14.
J Nanobiotechnology ; 19(1): 79, 2021 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-33740998

RESUMO

BACKGROUND: Osteosarcoma (OS) is the most common primary malignant bone tumor occurring in children and young adults. Drug-resistant osteosarcoma often results in chemotherapy failure. Therefore, new treatments aimed at novel therapeutic targets are urgently needed for the treatment of drug-resistant osteosarcoma. Mitochondria-targeted phototherapy, i.e., synergistic photodynamic/photothermal therapy, has emerged as a highly promising strategy for treating drug-resistant tumors. This study proposed a new nano-drug delivery system based on near-infrared imaging and multifunctional graphene, which can target mitochondria and show synergistic phototherapy, with preferential accumulation in tumors. METHODS AND RESULTS: Based on our previous study, (4-carboxybutyl) triphenyl phosphonium bromide (TPP), a mitochondria-targeting ligand, was conjugated to indocyanine green (ICG)-loaded, polyethylenimine-modified PEGylated nanographene oxide sheets (TPP-PPG@ICG) to promote mitochondrial accumulation after cellular internalization. Thereafter, exposure to a single dose of near-infrared irradiation enabled synergistic photodynamic and photothermal therapy, which simultaneously inhibited adenosine triphosphate synthesis and mitochondrial function. Induction of intrinsic apoptosis assisted in surmounting drug resistance and caused tumor cell death. After fluorescence imaging-guided synergistic phototherapy, the mitochondria-targeting, multifunctional graphene-based, drug-delivery system showed highly selective anticancer efficiency in vitro and in vivo, resulting in marked inhibition of tumor progression without noticeable toxicity in mice bearing doxorubicin-resistant MG63 tumor cells. CONCLUSION: The mitochondria-targeting TPP-PPG@ICG nanocomposite constitutes a new class of nanomedicine for fluorescence imaging-guided synergistic phototherapy and shows promise for treating drug-resistant osteosarcoma.


Assuntos
Neoplasias Ósseas/tratamento farmacológico , Grafite/farmacologia , Mitocôndrias/efeitos dos fármacos , Nanocompostos/química , Imagem Óptica/métodos , Osteossarcoma/tratamento farmacológico , Fototerapia/métodos , Animais , Apoptose/efeitos dos fármacos , Apoptose/efeitos da radiação , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/radioterapia , Linhagem Celular Tumoral , Doxorrubicina , Sistemas de Liberação de Medicamentos , Resistencia a Medicamentos Antineoplásicos , Fluorescência , Humanos , Hipertermia Induzida , Verde de Indocianina , Terapia a Laser , Masculino , Camundongos , Camundongos Nus , Nanopartículas/uso terapêutico , Osteossarcoma/diagnóstico por imagem , Osteossarcoma/radioterapia , Óxidos , Oxigênio , Fotoquimioterapia/métodos , Polietilenoimina , Ensaios Antitumorais Modelo de Xenoenxerto
15.
J Colloid Interface Sci ; 583: 288-298, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33007585

RESUMO

With the increasing demand for miniaturization and portable energy storage system, it is an urgent necessary that developing high volumetric energy density supercapacitors with small volumes. Herein, an integrated self-supporting CoZnNiS@CNTs/rGO composite film electrode with the thickness of about 6 µm was designed. In the unique structure, porous CNTs/rGO film is served as conductive substrate to support the CoZn-MOFs derived vertically oriented two-dimensional CoZnNiS nanoarrays. The self-supporting film endows the electrode a high volumetric mass density of 1.28 g cm-3 and superior electron-ion transport channel, which displays a maximum specific capacitance of 1349.2 F g-1 as well as high volumetric capacity of 1727.0 F cm-3 at 1 A g-1. Besides, a porous film of pure carbon materials (carbon spheres integrated graphene) was designed and used as the negative electrode in supercapacitor. When assembled a hybrid supercapacitor based on the above two self-supporting electrodes, the device delivers up an ultra-high volumetric/gravimetric energy density of 65.2 W h L-1 (60.4 W h kg-1) at a power density of 1308 W L-1 (1200 W kg-1). Moreover, the asymmetric supercapacitor also displays an ultra-long lifetime with 90.6% retention after 10,000 cycles. These outstanding performances make the CoZnNiS@CNTs/rGO electrode could be a promising candidate for next-generation high volumetric/gravimetric energy density supercapacitors, especially in the limited space.

16.
Nat Med ; 26(6): 845-848, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32350462

RESUMO

We report acute antibody responses to SARS-CoV-2 in 285 patients with COVID-19. Within 19 days after symptom onset, 100% of patients tested positive for antiviral immunoglobulin-G (IgG). Seroconversion for IgG and IgM occurred simultaneously or sequentially. Both IgG and IgM titers plateaued within 6 days after seroconversion. Serological testing may be helpful for the diagnosis of suspected patients with negative RT-PCR results and for the identification of asymptomatic infections.


Assuntos
Anticorpos Antivirais/sangue , Formação de Anticorpos/efeitos dos fármacos , Betacoronavirus/patogenicidade , Infecções por Coronavirus/tratamento farmacológico , Pneumonia Viral/tratamento farmacológico , Adulto , Idoso , Formação de Anticorpos/imunologia , Antivirais/uso terapêutico , Betacoronavirus/genética , COVID-19 , Infecções por Coronavirus/sangue , Infecções por Coronavirus/imunologia , Infecções por Coronavirus/virologia , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Masculino , Pessoa de Meia-Idade , Pandemias/prevenção & controle , Pneumonia Viral/sangue , Pneumonia Viral/imunologia , Pneumonia Viral/virologia , SARS-CoV-2
17.
Medicine (Baltimore) ; 99(13): e19377, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32221065

RESUMO

BACKGROUND: MRI findings of carotid plaque components have been studied recently as a tool to predict recurrent ischemic events. We performed a systematic review and meta-analysis to summarize the association of MRI-determined intraplaque hemorrhage, lipid-rich necrotic core, and thinning/rupture of the fibrous cap with recurrent ischemic events. METHODS: Electronic search was performed in PUBMED, EMBASE, Cochrane Controlled Register of Trials (CENTRAL) from inception to Oct 30, 2018. We included cohort studies with an average follow-up time of more than 1 month in which intraplaque hemorrhage, lipid-rich necrotic core, or thinning/rupture of the fibrous cap were associated with recurrent ipsilateral stroke or ischemic events. We performed heterogeneity assessment before carrying out meta-analysis. According to the heterogeneity, we selected fixed-effect model for meta-analysis of the included cohort studies. RESULTS: Using a prespecified search strategy, of the 2128 articles, 6 studies with a total number of 621 participants met eligibility for systematic review and meta-analysis. The hazard ratios of intra-plaque hemorrhage, thinning/rupture of the fibrous cap and lipid rich necrotic core as recurrent Stroke/Transient ischemic attack (TIA) were 7.14(95% confidence interval, 4.32 to 11.82), 5.68(95% confidence interval, 2.40 to 13.47), and 2.73(95% confidence interval, 1.04 to 7.16), respectively. No significant heterogeneity was found in the 3 meta-analyses. CONCLUSIONS: The presence of intraplaque hemorrhage, lipid-rich necrotic core, and thinning/rupture of the fibrous cap on MRI of carotid plaque are strong predictors of recurrent stroke events. However, due to the lack of original studies, larger cohort studies are warranted.


Assuntos
Estenose das Carótidas/epidemiologia , Estenose das Carótidas/patologia , Ataque Isquêmico Transitório/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Hemorragia/etiologia , Humanos , Imageamento por Ressonância Magnética , Necrose/etiologia , Estudos Prospectivos
18.
Am J Transl Res ; 11(11): 7009-7017, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31814904

RESUMO

Accumulating evidence showed that lncRNAs play important roles in tumour development. Recently, a novel lncRNA DLX6-AS1 was found to be overexpressed in some tumors such as lung adenocarcinoma, renal cell carcinoma and hepatocellular carcinoma. However, the functional roles of DLX6-AS1 in laryngeal squamous cell carcinoma (LSCC) are still unclear. In the study, we showed that the expression level of DLX6-AS1 was upregulated in the LSCC samples compared to the noncancerous tissues. By using CCK-8 analysis, we demonstrated that knockdown expression of DLX6-AS1 suppressed the Hep2 cell growth. DLX6-AS1 knockdown inhibited the Hep2 cell cycle and invasion. MiR-376c was identified to have the complementary binding sites with the DLX6-AS1. By luciferase reporter assay, we indicated that overexpression of miR-376c inhibited the luciferase activity of wild-type DLX6-AS1, but it failed to suppress luciferase activity of mutated one. DLX6-AS1 knockdown enhanced the expression of miR-376c in the Hep2 cell. Moreover, we showed that the expression level of miR-376c was lower in the LSCC samples than in the noncancerous tissues and the expression of miR-376c was negatively correlated with expression of DLX6-AS1 in LSCC tissues. Ectopic expression of miR-376c suppressed cell proliferation, cycle and invasion of LSCC cell. DLX6-AS1 knockdown suppressed cell proliferation, cycle and invasion via regulating miR-376c expression. These data proved that lncRNA DLX6-AS1 might play as an oncogene in LSCC development and tumorigenesis.

19.
Proc Biol Sci ; 285(1893): 20182035, 2018 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-30963908

RESUMO

Diversity-invasion resistance relationships are often variable and sensitive to environmental conditions such as resource availability. Resource stoichiometry, the relative concentration of different elements in the environment, has been shown to have strong effects on the physiology and interactions between different species. Yet, its role for diversity-invasion resistance relationships is still poorly understood. Here, we explored how the ratio of nitrogen (N) and phosphorus affects the productivity and invasion resistance of constructed microbial communities by a plant pathogenic bacterium, Ralstonia solanacearum. We found that resource stoichiometry and species identity effects affected the invasion resistance of communities. Both high N concentration and resident community diversity constrained invasions, and two resident species, in particular, had strong negative effects on the relative density of the invader and the resident community productivity. While resource stoichiometry did not affect the mean productivity of the resident community, it favoured the growth of two species that strongly constrained invasions turning the slope of productivity-invasion resistance relationship more negative. Together our findings suggest that alterations in resource stoichiometry can change the community resistance to invasions by having disproportionate effects on species growth, potentially explaining changes in microbial community composition under eutrophication.


Assuntos
Fenômenos Fisiológicos Bacterianos , Microbiota/fisiologia , Nitrogênio/metabolismo , Fósforo/metabolismo , Ralstonia solanacearum/fisiologia , Bactérias/classificação , Espécies Introduzidas , Dinâmica Populacional
20.
Cardiology ; 130(3): 143-52, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25633973

RESUMO

OBJECTIVE: To investigate the mechanism of Krüppel-like factor 15 (KLF15) in cardiac remodeling and interstitial fibrosis. METHODS: A rat model was established by in vivo aortic coarctation followed by a period of pressure unloading and used to measure heart function, myocardial pathological changes, and KLF15, transforming growth factor-ß (TGF-ß), connective tissue growth factor (CTGF), and myocardin-related transcription factor A (MRTF-A) expression levels. In addition, cardiac fibroblasts were cultured in vitro and treated with KLF15-shRNA or KLF15 recombinant adenovirus to establish a TGF-ß-mediated cardiac fibroblast hypertrophy model and analyze cell morphology, collagen secretion, and changes in the expression levels of 4 cytokines. RESULTS: In vivo pressure overload impaired cardiac function and resulted in myocardial hypertrophy and fibrosis. These changes were accompanied by the downregulation of KLF15 mRNA levels and increased expression of the other factors. The response to unloading was the opposite. In in vitro cell experiments, by specifically targeting the KLF15 gene, changes in the expression levels of the 4 cytokines and the amounts of collagen I and III were observed. CONCLUSIONS: In myocardial remodeling processes induced by mechanical or metabolic factors, KLF15 regulates TGF-ß, CTGF, and MRTF-A expression and can ameliorate or even reverse myocardial fibrosis and improve cardiac function.


Assuntos
Cardiomegalia/genética , Insuficiência Cardíaca/genética , Fatores de Transcrição Kruppel-Like/metabolismo , Miocárdio/patologia , Animais , Células Cultivadas , Colágeno/genética , Fator de Crescimento do Tecido Conjuntivo/genética , Fator de Crescimento do Tecido Conjuntivo/metabolismo , Citocinas/metabolismo , Modelos Animais de Doenças , Ecocardiografia , Fibroblastos , Fibrose , Testes de Função Cardíaca , Fatores de Transcrição Kruppel-Like/genética , Masculino , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Ratos , Ratos Sprague-Dawley , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo , Fator de Crescimento Transformador beta/genética , Fator de Crescimento Transformador beta/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...